Inolife AquaLight DW10 UV disinfection series are designed energy-efficient UV solution for the disinfection of drinking water, process water and other liquids which have high turbidty. Our disinfection system is utilizied many outstanding company in Europe. Inolife disinfection systems performance is proved by laboratory that more than 99,99% of all pathogens can be rendered ineffective such as Cryptosporidium, Giardia, E.coli, Salmonella typhii, Pseudomonas aeruginosa, rotavirus. Disinfected liquids (water) have no unpleasent taste or odour. Uv treatment is a kind of physical disinfection methods, water and other liquids are disinfected without using additional chemicals and this UV does not cause formation of by-products such as THM-Trihalomethans, haloacetanitriles, chlorite, chlorate and haloacetic acids. Uv technology is more safer method for your employees, your society and environment. UV disinfection is contributed of handling of hazardous chemicals and keeping your treatment plant safely. UV solution leads to higher efficiency and operational safety.
Inolife AquaLight DW10 series compact UV units designed to treat flow rate of 4 to 35 m3/hour for using municipal and industrial drinking water disinfection applications. AquaLight UV systems can design various sizes according to customer’s need. Units have high output-low pressure amalgam lamps and ballasts. Ultasound system is enhanced of UV disinfection performance. Ultrasound system is also supported cleaning system. An automatic cleaning system keeps the sleeves clean and thus UV lamps life guarentee are extended 12000 hours.
The high-output low pressure amalgam lamps are used in the units in order to minimize capital and operating costs. Compact chamber and integrated fan is controlled of the temperature increasing in the system in order to enhance performance. AquaLight’s series of innovative UV treatment systems are tested and patented by institutes in Germany and Turkey.
Inolife ensures best possible design according to customers specific needs. Recommended industries and applications are,
Inolife AquaLight Series Disinfection System is consisted of key components.
High Efficiency Amalgam Lamps: In our systems, high efficiency and low-pressure amalgam lamps are used. These lamps provide the dose and compact reactor design required for the system. Each lamp is placed into its own protective quartz glass covers, and cover holders are specially designed to be replaced easily upon expiry of UV lamps.
UV Reactor: Body made of 304L stainless steel was optimized to obtain optimal UV powder dispersion. 316 L stainless steel reactors can be also used on the basis of projects for special use areas in the industry. There are various body configurations with variable inlet/outlet diameters. Maximum pressure is 10 bar (145 psi).
Control Panel: Epoxy coated control panel is located on the reverse of the device. All UV functions (UV reactor, UV sensor) and automatic cleaning system are controlled through this panel. UV density and continuous monitoring of the lamps can be followed up through the monitor installed on the front of the device. Also, when the device exceeds alarm limits, it can be integrated with GSM module that sends SMS to a recipient.
Cleaning System; The system, which can be controlled through the front panel, can automatically activate depending upon the pollution of quartz glass and reduction of performance percentage of UV lamps and start to clean the system and also can be activated manually in case of need. The system starts the cleaning operation with the special solution in the cleaning tank on the time indicated according to the pollution ratio and returns to the disinfection process after completing the cleaning operation.
UV sensor: DVGW-approved UV sensors can make very precise measurements in line with our UV disinfection systems by monitoring the rays of low-pressure UV lamps.
Ultrasonic System: Operating frequency of ultrasonic transductor that is made of stainless steel material is adjusted to 40 kHz to prevent acoustic irregularity. The reason for choosing this frequency range is to assist with disinfection and to support system cleaning by ensuring high turbulence /mixing.
Model Name |
AquaOneLight DW 10-1 T |
AquaFourLight DW 10 - 4T |
AquaFourLight DW 10 – 4 TK |
AquaSixLight DW 10-6 i |
---|---|---|---|---|
Total System Weight | 55 kg | 75kg | 75kg | 82 kg |
Dimensions | ||||
Tatal Height (Including Monitor) (A) | 1440 mm | 1440 mm | 1440 mm | 1440 mm |
System Width (B) | 512 mm | 512 mm | 512 mm | 512 mm |
System Width (Including Valves) (C) | 605 mm | 976 mm | 976 mm | 976 mm |
System Depth (D) | 537 mm | 507 mm | 507 mm | 507 mm |
Liquid Feed Connection Height (E) | 635 mm | 567 mm | 567 mm | 567 mm |
Drainage Connection Height (F) | 214 mm | 281 mm | 281 mm | 281 mm |
Distance Between Connections (G) | 420 mm | 287mm | 287 mm | 287 mm |
Electrical Properties |
||||
Power Supply | 230 V AC 50/60Hz | 230 V AC 50/60Hz | 230/400 V AC 50/60Hz | 230V AC 50/60 Hz |
Power Consumption | 0.8 KW | 1.8 KW | 1.9 KW | 2.1 KW |
Disinfection Unit |
||||
Reactor Volume | 8 liters | 58 liters | 58 liters | 54 liters |
Max. Operating Pressure | 6 bar | 6 bar | 6 bar | 6 bar |
Max. Test Pressure | 10bar | 10bar | 10bar | 10 bar |
Flow Rate | 4 m3/hour | 10-35 m3/hour | 10-35 m3/hour | 5-35 m3/hour |
Water Connection | ¾ inch | DN 65 | DN 65 | DN65 |
Protection | IP23 | IP23 | IP23 | IP23 |
Safety Valve | Actuator Valve 3/4" | Actuator Butterfly Valve DN65 | Actuator Butterfly Valve DN65 | Actuator Butterfly Valve DN65 |
UV- System |
||||
Number of UV Lamps | 1 | 4 | 4 | 6 |
UV-C Wavelength | 254nm | 254nm | 254nm | 254nm |
Output Voltage of UV Lamps | 135/ 45 W UV-C / For 254 nm: 90 V +- 5 | 135/ 45 W UV-C | 135/ 45 W UV-C | 135/45 W UV-C |
Type of UV Lamps | Low-Pressure Amalgam Lamps | Low-Pressure Amalgam Lamps | Low Pressure Amalgam Lamps | Low Pressure Amalgam Lamps |
Lifetime Of the UV Lamps | 10000-12000 hours | 8000-12000 hours | 8000-12000 hours | 8000-12000 hours |
Ultrasound System |
||||
Ultrasonic Transducer | 4 | 1 | 1 | 1 |
Ultrasonic Generator | 1 | 1 | 1 | 1 |
Frequency | 40kHz | 40kHz | 40kHz | 40kHz |
Ultrasonic Power | RF Max.Power 200W / Absorbtion: 400W | RF Max.Power 400W / Absorbtion: 600W | RF Max. Power 400W / Absorbtion: 600W | RF Max.Power 400W / Absorbtion: 600W |
Additional Informations |
||||
Fan | 1 | - | 4 | - |
Active Carbon Filter | - | - | - | - |
Steel Filter | - | - | - | - |
Max. Operating Temperature | 70°C | 45°C | 70°C | 45°C |
Max. Ambient Temperature | 40°C | 40°C | 40°C | 40°C |